AUTOCLAVE MACHINE IN SARAWAK
SA-232X
Just Filling water, set the sterilization program and start. The sterilizer is designed for automatic sterilization without any additional operate, only need to do is wait for it to be completed.
Intuitive indicators, you can easily track each phase of the sterilization process and be alerted when sterilization is complete.
Automatic pressure release and water drain, greatly shorten the sterilization cycle time.
When the sterilization is completed, it will automatically enter the drying program by air pump. Closed door drying improves the 90% Drying efficiency.
Using high efficiency HEPA air filter, the filtering effect of air particles below 0.03μm is over 99.99% to ensure that the sterilized items are not affected by the external environment and remain sterilized during the drying process. The air filter not only meets the requirements of EN 13060 for air filters, but also meets the BFE and VFE filtration efficiency as high as 99.999%.
Sturdy is manufactured in compliance with the following directives and standards:
Autoclave Machine in Sarawak & Sabah
SPEC/Model NO. | SA-230FA |
---|---|
Chamber Volume | 16 Liters / 4.2 Gallons |
Chamber Size (Diameter x Depth) | Ø 230 x 410 (mm) Ø 9.06 x 16.14 (inch) |
Overall Dimensions (W x H x D) | 501 X 406 X 537 (mm) 19.72 x 15.98 x 21.14 (inch) |
Net Weight | 28 kg / 62 Ibs |
Water Fill | Tank-Man* |
Water Tank Volume | 4200 (cc) |
Water Consumption (per cycle) | 300-450 (cc) |
Control System | Microprocessor |
Temperature Options | 118 ~ 134 (°C) |
Sterilization Time | 4 / 15 / 30 (min) |
Dry (Optional) | Auto Exhaust and Drain, Closed Door Drying with Air Pump |
Dry Time (Optional) | 18 (min) |
Voltage(V) | 230V / 110V, 50/60Hz |
Safety Device | • Pressure Auto Door Lock • Overheat Protection • Door Safety Latch • Pressure Overload Protection |
Standards and Directives | • PED 2014/68/EU (Pressure Equipment Directive) • EN 61010-1 (Safety Requirements for measurement control and laboratory use) • EN 61010-2-040 ( Safety requirements for sterilizers used to treat medical materials) • EN 61326-1 (EMC; Electrical equipment for measurement, control and laboratory use) • ISO 13485:2016 Medical Devices - Quality Management Systems • RoHS (Restriction of Hazardous Substances Directive 2011/65/EU) |
For all your autoclave needs in Sarawak & Sabah, Pflege Medical Supplies Sdn Bhd is your trusted supplier. Whether for medical, dental, or laboratory applications, our autoclaves cater to diverse requirements. Additionally, our dedicated service and warranty division is always ready to assist you, ensuring the longevity and optimal performance of your autoclave.
Choose Pflege Medical Supplies Sdn Bhd for cutting-edge autoclave solutions that prioritize your safety and satisfaction.